Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dialogues Health ; 4: 100178, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38665133

RESUMO

Sick Building Syndrome (SBS) is an illness among workers linked to time spent in a building. This study aimed to investigate the Indoor Air Quality (IAQ) and symptoms of Sick Building Syndrome (SBS) among administrative office workers. The IAQ parameters consist of ventilation performance indicators, and physical and chemical parameters were measured using specified instruments for three days during weekdays. The SBS symptoms were assessed by a questionnaire adopted from the Industry Code of Practice of Indoor Air Quality (ICOP-IAQ) 2010 among 19 employees from the office in East Coast Malaysia. Relationship between past symptoms and present symptoms which are draught (past symptoms) with feeling heavy headed (present symptoms) (r = 0.559, p < 0.05), room temperature too high (past symptoms) was highly correlated with feeling heavy headed (present symptoms) (r = 0.598, p < 0.01) and cough (present symptoms) (r = 0.596, p < 0.01). Room temperature (past symptoms) has a positive medium relationship with cough (present symptoms) (r = 0.477, p < 0.05) and scaling itching scalp or ears (present symptoms) has a relationship between stuffy bad air (r = 0.475, p < 0.05) and dry air (r = 0.536, p < 0.05). There was a significant association between RH with drowsiness (χ2 = 7.090, p = 0.049) and dizziness (χ2 = 7.090, p = 0.049). The association was found between temperature and SBS symptoms between temperature with headache (χ2 = 7.574, p = 0.051), feeling heavy-headed (χ2 = 8.090, p = 0.046), and skin rash itchiness (χ2 = 7.451, p = 0.044). Air movement also showed a positive association with symptoms of feeling heavy-headed (x2 = 8.726, p = 0.021). PM10 has positive significance with SBSS which are feeling heavy-headed (χ2 = 7.980, p = 0.023), and eyer's irritation (χ2 = 7.419, p = 0.038). The conclusion of this study showed that there were positive significant between temperature and relative humidity toward SBSS.

2.
Sci Total Environ ; 729: 139022, 2020 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-32353722

RESUMO

An outbreak of respiratory illness which is proven to be infected by a 2019 novel coronavirus (2019-nCoV) officially named as Coronavirus Disease 2019 (COVID-19) was first detected in Wuhan, China and has spread rapidly in other parts of China as well as other countries around the world, including Malaysia. The first case in Malaysia was identified on 25 January 2020 and the number of cases continue to rise since March 2020. Therefore, 2020 Malaysia Movement Control Order (MCO) was implemented with the aim to isolate the source of the COVID-19 outbreak. As a result, there were fewer number of motor vehicles on the road and the operation of industries was suspended, ergo reducing emissions of hazardous air pollutants in the atmosphere. We had acquired the Air Pollutant Index (API) data from the Department of Environment Malaysia on hourly basis before and during the MCO with the aim to track the changes of fine particulate matter (PM2.5) at 68 air quality monitoring stations. It was found that the PM2.5 concentrations showed a high reduction of up to 58.4% during the MCO. Several red zone areas (>41 confirmed COVID-19 cases) had also reduced of up to 28.3% in the PM2.5 concentrations variation. The reduction did not solely depend on MCO, thus the researchers suggest a further study considering the influencing factors that need to be adhered to in the future.


Assuntos
Poluição do Ar , Betacoronavirus , Infecções por Coronavirus , Pandemias , Pneumonia Viral , COVID-19 , China , Humanos , Malásia , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...